Product Banner

Frecon FR01 Series Smart Inverter

Frecon FR01 Series Smart Inverter Supplier

Square Plus Pattern


FR01 Series Smart Inverter
Frecon FR01 Series Smart Inverter :-
  • Book-type narrow body design, small size
  • Independent air duct design, high protection
  • Parameter setting is time-saving and eƉ cient
  • Ever more intuitive and user-friendly programming & menus
  • Electronic jumper design, convenient and easy to use
  • Detachable keypad design, multi-scenario application
  • Compatible with standard rail installation, easy to install
  • Installed side by side at zero distance, high space utilization
  • Enhanced conformal coating to adapt to harsh environments

Model Description

FR01
1

2
4
3
T
4
0.7
5
B
6

  • Series Name
    FR01 Smart Inverter
  • Industry-specific series code
    Blank: Standard machine
    A~Z: Industry-specific retention
  • Input voltage level
    2: 220V(-15% ~ +20%)
    4: 380V(-15% ~ +30%)
  • Input voltage phase
    S: Single Phase
    T: Three Phase
  • Adaptable motor power
    Number 0.4 0.7 1.5 2.2 ...
    Adaptable Motor (kW) 0.4 0.75 1.5 2.2 ...
  • Brake unit
    Blank: No built-in brake unit
    B: Built-in brake unit
Square Plus Pattern


Electric Specification :-
Model Power Capacity
KVA
Rated input
current (A)
Rated output
current (A)
Adapted Motor
kW HP
Single phase: 220V, 50/60Hz Range: -15% ~ +20%
FR01-2S-0.4B-H 1.0 6.5 2.5 0.4 0.5
FR01-2S-0.7B-H 1.5 9.3 4.2 0.75 1.0
FR01-2S-1.5B-H 3.0 15.7 7.5 1.5 2
FR01-2S-2.2B-H 4.0 24 9.5 2.2 3
FR01-2S-4.0B-H 6.0 30 17 4.0 5
Three phase: 380V, 50/60Hz Range: -15% ~ +30%
FR01-4T-0.4B-H 1.0 2.5 1.6 0.37 0.5
FR01-4T-0.7B-H 1.5 3.4 2.5 0.75 1
FR01-4T-1.5B-H 3.0 5.8 4.2 1.5 2
FR01-4T-2.2B-H 4.0 5.8 5.5 2.2 3
FR01-4T-4.0B-H 6 11 9.5 4 5
FR01-4T-5.5B-H 8.9 14.6 13 5.5 7.5
FR01-4T-7.5B-H 11 20.5 17 7.5 10
Electric Specification :-
Item Specifications
Input power Rated input voltage (V) 1-Phase 220V (±15%~±20%)
3-Phase 380V (±15%~±30%)
Rated input frequency (Hz) 50Hz/60Hz, ±5%
Output power Rated output voltage (V) 0~rated input voltage, error ±3%
Rated output frequency (Hz) 0.00~600.00 Hz, unit: 0.01Hz
Control characteristics Control mode V/F control; Sensor-less vector control 1; Sensor-less vector control 2
Speed range 1:50 (V/F control)
1:100 (sensor-less vector control 1)
1:200 (sensor-less vector control 2)
Speed control precision ±0.5% (V/F control); ±0.2% (sensor-less vector control 1 & 2)
Speed fluctuation ±0.3% (sensor-less vector control 1 & 2)
Torque response <10ms (sensor-less vector control 1 & 2)
Starting torque 0.5Hz: 150% (V/F control, sensor-less vector control 1)
0.25Hz: 150% (sensor-less vector control 2)
Basic functions Carrier frequency 0.7kHz~16kHz
Overload capability 150% rated current 60s, 180% rated current 10s, 200% rated current 1s
Torque boost Automatic torque boost, Manual torque boost 0.1%~30.0%
V/F Curve Three mode: straight; multi-point type; N Th-type V/F curve
Acceleration and deceleration Curve Line or curve acceleration and deceleration mode. Four kinds of acceleration and deceleration time, Ramp Time Range: 0.0~6000.0s
DC brake DC brake start frequency: 0.00~Max Hz
DC brake time: 0.0s~10.0s
DC brake current: 0.0%~150.0%
Operate Command source Given the control panel, control terminal, serial communication port given
Frequency given 9 kinds of frequency sources
Input terminal 4 channel switch input terminals, one channel to make high-speed pulse input. 1 channel analog inputs, 0~10V / 0~20mA voltage and current options
Output terminal 1 channel switch output terminal
1 relay output terminals
1 analog output terminal
Protection Provide fault protection dozen: Over-current, Over-voltage, Under-voltage, Over-temperature, Over-load Etc Protection
Keypad LED Display Display Parameters
Key lock and function selection Realize some or all of the keys locked, scope definition section keys to prevent misuse
Run and stop monitoring information In the run or stop can be set to monitor U00 group 4 objects were
Environment Operation Place Indoors, no direct sunlight, no dust, no corrosive gases, no flammable gases, no oil mist, no water vapor, no water drop and salt, etc
Altitude 0~2000m, De-rate 1% for every 100m when the altitude is above 1000 meters
Ambient temperature -10℃~40℃ (When environment temperature above 40℃, derating use)
Others Installation Wall-mounted or Flange mounting
IP grade IP20
Cooling method Forced air cooling

Scan the QR to call

RB Automation