Product Banner

RX Series Pulse type small PLC-RX3U

img
img
img
img
img

RX Series Pulse Type Small PLC-RX3U Overview

Rtelligent RX series programmable logic controller RX3U-32MR/MT, switching up to 16 in and 16 out, outputs can be selected from transistor or relay outputs. Comes with a Type-C programming interface, routinely equipped with two RS485 interfaces, a CAN interface, support for YO-Y2 a total of three 150kHz high-speed pulse output, support for variable-speed, uniform-speed pulse single-axis output, command specifications compatible with the Mitsubishi FX3U series. eed, uniform pulse single-axis output.

  • Switching up to 16 in 16 out, support transistor or relay outputs for output
  • Type-C programming interface
  • Two RS485 interfaces and one CAN interface
  • Support YO-Y2 3-channel 150kHz high-speed pulse output
icon icon

Naming Rule

RX3U
1
-

32
2
M
3
R
4

  • Series Name
    RM3U Series programmable logic controller
  • Input & Output points
    32 : Input & Output total 32 points
  • Module Category
    Universal master controller module
  • Output type
    R : Relay output
    T : Transistor NPN output

*Model naming rules are only used for model meaning analysis.
For specific optional models, please refer to the details page.

io-speed-regulating-stepper-motor
RX3U-32MR RX3U-32MT
Input Voltage DC 24V, Voltage range: 20.4 ~ 28.8V
Number of digital input points 16-point bipolar input 16-point bipolar inputs (high-speed input points)
X0, X1, X3, X4 can only be co-positive
Isolation method Optocoupling Optocoupling
Input Impedance Normal input 2.4KΩ High speed input 2.4KΩ
Input is ON Input current greater than 9.9mA/24V on normal inputs High speed input input current >5.8mA/24V /15 VDC, 2.5mA
Input is OFF Input current less than 4mA/17V on normal inputs High speed input current less than 4.5mA/19V
Filtering function There is a filter function, the filter range in the 0–60ms range can be set, the default 10ms
High-speed counting function Conventional 6-channel single-phase 60K, or AB-phase 2-channel 30K. X0/1/3/4 for up to 480K
Input level Drain/Source, S/S to 24V for NPN, S/S to GND for PNP. High-speed counting only supports S/S connection 24V
Incommunication Isolation (on-site and logical) isolation group, 500VAC, 1 minute, see wiring diagram
Number of digital output points 16-point relay output 16 point NPN output
Operating temperature 0°C ~ 55°C
Humidity 5% ~ 95% (no condensation)
Altitude -1000m ~ +2000m
Air Dust-proof, non-corrosive, lower salt spray, humidity, dust and fog environments, SO2 < 0.5ppm, H2S < 0.1ppm, RH < 60%, no condensation
Insulation voltage / High voltage insulation DC 500V 2MΩ or above / end-to-ground 2200VDC, I/O interface end-to-other end 1500VAC (1 minute)
Storage temperature -25 ~ 70°C
Resistance to electrical interference Pulse width 50ns, repetition frequency 5kHz, 2kV peak voltage / noise voltage 1kVp-p, 1μs pulse 1 minute
Electrostatic discharge Contact discharge: ±4KV, Air discharge: ±8KV
Electrically fast transient pulse groups Power line: 2KV, 5KHz
Signal line: 2KV, 5KHz (I/O coupling clip), 1KV, 5KHz (communication coupling clip)
Vibration resistance Frequency 10 ~ 57Hz, amplitude 0.1mm; frequency 57 ~ 150Hz, acceleration 1.0g, three-dimensional direction each 10 times
Shock resistance 15g for 11ms, 3 impacts in 3D direction
Grounding (FG) Third type of grounding (not common to strong electrical system)
square-plus-pattern

Inquiry Now

Scan the QR to call

RB Automation