RX Series Pulse Type Small PLC-RX3U Overview
Rtelligent RX series programmable logic controller RX3U-32MR/MT, switching up to 16 in and 16 out, outputs can be selected from transistor or relay outputs. Comes with a Type-C programming interface, routinely equipped with two RS485 interfaces, a CAN interface, support for YO-Y2 a total of three 150kHz high-speed pulse output, support for variable-speed, uniform-speed pulse single-axis output, command specifications compatible with the Mitsubishi FX3U series. eed, uniform pulse single-axis output.
- Switching up to 16 in 16 out, support transistor or relay outputs for output
- Type-C programming interface
- Two RS485 interfaces and one CAN interface
- Support YO-Y2 3-channel 150kHz high-speed pulse output
Naming Rule
RX3U
1
-
32
2
M
3
R
4
- Series Name
RM3U Series programmable logic controller - Input & Output points
32 : Input & Output total 32 points - Module Category
Universal master controller module
- Output type
R : Relay output
T : Transistor NPN output
*Model naming rules are only used for model meaning analysis.
For
specific
optional models, please refer to the details page.
| RX3U-32MR | RX3U-32MT | |
|---|---|---|
| Input Voltage | DC 24V, Voltage range: 20.4 ~ 28.8V | |
| Number of digital input points | 16-point bipolar input |
16-point bipolar inputs (high-speed input points) X0, X1, X3, X4 can only be co-positive |
| Isolation method | Optocoupling | Optocoupling |
| Input Impedance | Normal input 2.4KΩ | High speed input 2.4KΩ |
| Input is ON | Input current greater than 9.9mA/24V on normal inputs | High speed input input current >5.8mA/24V /15 VDC, 2.5mA |
| Input is OFF | Input current less than 4mA/17V on normal inputs | High speed input current less than 4.5mA/19V |
| Filtering function | There is a filter function, the filter range in the 0–60ms range can be set, the default 10ms | |
| High-speed counting function | Conventional 6-channel single-phase 60K, or AB-phase 2-channel 30K. X0/1/3/4 for up to 480K | |
| Input level | Drain/Source, S/S to 24V for NPN, S/S to GND for PNP. High-speed counting only supports S/S connection 24V | |
| Incommunication | Isolation (on-site and logical) isolation group, 500VAC, 1 minute, see wiring diagram | |
| Number of digital output points | 16-point relay output | 16 point NPN output |
| Operating temperature | 0°C ~ 55°C | |
| Humidity | 5% ~ 95% (no condensation) | |
| Altitude | -1000m ~ +2000m | |
| Air | Dust-proof, non-corrosive, lower salt spray, humidity, dust and fog environments, SO2 < 0.5ppm, H2S < 0.1ppm, RH < 60%, no condensation | |
| Insulation voltage / High voltage insulation | DC 500V 2MΩ or above / end-to-ground 2200VDC, I/O interface end-to-other end 1500VAC (1 minute) | |
| Storage temperature | -25 ~ 70°C | |
| Resistance to electrical interference | Pulse width 50ns, repetition frequency 5kHz, 2kV peak voltage / noise voltage 1kVp-p, 1μs pulse 1 minute | |
| Electrostatic discharge | Contact discharge: ±4KV, Air discharge: ±8KV | |
| Electrically fast transient pulse groups |
Power line: 2KV, 5KHz Signal line: 2KV, 5KHz (I/O coupling clip), 1KV, 5KHz (communication coupling clip) |
|
| Vibration resistance | Frequency 10 ~ 57Hz, amplitude 0.1mm; frequency 57 ~ 150Hz, acceleration 1.0g, three-dimensional direction each 10 times | |
| Shock resistance | 15g for 11ms, 3 impacts in 3D direction | |
| Grounding (FG) | Third type of grounding (not common to strong electrical system) | |
Inquiry Now
Scan the QR to call
Submit Inquiry for
×